The gyroscope with long life time, wide measurement range and high reliability has been widely used in requirements of strapdown inertial measurement unit, also can be used for high dynamic transporter attitude system.
Performance
Parameter Random Drift (1σ) ≤0.1°/h
Drift Stability (1σ) ≤0.3°/h
g-independent ≤15°/h
g-dependent ≤8°/h
Frequency Response ≥70Hz
Technological parameter Power Supply(Three Phase) 500 Hz
16V
Power Supply(Single Phase) 16 KHz
5 V
Synchronous Speed 10,000
Synchronizing Time ≤10 S
Output Gradient 10~14 mv/’
Master torquer 7±1 Ω
Vice control torquer 2±0.5 Ω
Torquer scale factor Master torquer ≥600 °/h/mA
Vice control torquer ≥10 °/h/mA
Max.Tracking Speed ≥200 °/s
Output Nonlinearity ≤0.5%
Life Time ≥3000
Operating Temperature -40~+65℃
Shock Overload(8ms) ≥60 g
Physical Parameter Dimension Φ34×64 mm
Mounting flanges 36×36 mm
Weight ≤320 g
Performance
Parameter Random Drift (1σ) ≤0.1°/h
Drift Stability (1σ) ≤0.3°/h
g-independent ≤15°/h
g-dependent ≤8°/h
Frequency Response ≥70Hz
Technological parameter Power Supply(Three Phase) 500 Hz
16V
Power Supply(Single Phase) 16 KHz
5 V
Synchronous Speed 10,000
Synchronizing Time ≤10 S
Output Gradient 10~14 mv/’
Master torquer 7±1 Ω
Vice control torquer 2±0.5 Ω
Torquer scale factor Master torquer ≥600 °/h/mA
Vice control torquer ≥10 °/h/mA
Max.Tracking Speed ≥200 °/s
Output Nonlinearity ≤0.5%
Life Time ≥3000
Operating Temperature -40~+65℃
Shock Overload(8ms) ≥60 g
Physical Parameter Dimension Φ34×64 mm
Mounting flanges 36×36 mm
Weight ≤320 g