Applications:
For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high voltage) and the secondary (electronic) circuits.
Main Technical Data:
1. Primary normal current IPN: 10mA r.m.s
2. Primary current, measuring range IP: 0~+/-20mA
3. Primary normal current IPN: 4mA r.m.s
4. Measuring resistance: RMmin RMmax
with +/-15V @ +/-10mA max: 0 ohm 200 ohm
@ +/-20mA max: 0 ohm 65 ohm
5. Secondary normal current: 50mA rms
6. Conversion ratio: 10000:2000
7. Supply voltage(+/-5%): +/-15V
8. Current consumption: 15mA+ Secondary output current
9. Isolation test: Between the primary circuit and the secondary circuit(+.-.M): 6kVrms/50Hz/1min
Accuracy - Dynamic Performance Data:
1. Accuracy @ VPN, TA=+25¢XC: +/-1%
2. Non-linearity: better than +/-0.1%
3. Offset current @ IP=0, TA=+25¢XC: not more than +/-0.3mA
4. Thermal drift: +/-0.6mA(0¢XC ~+70 ¢XC)
5. Response time @90% of VPN: 20us~100us
General Data:
1. Operating temperature: 0¢XC ~+70¢XC
2. Storage temperature: -25¢XC ~+85¢XC
3. Primary coil resistance @ TA=+85 ¢XC: 2000 ohm
6. Secondary coil resistance: not more than 60 ohm
7. Weight: 500g
8. Standards: EN50178
Please also see our hot products as below:
automatic toilet flusher
voltage sensor
automatic sensing faucet
automatic soap dispenser
current sensors
sensor faucet
automatic hand dryer
automatic faucet
voltage transducer
automatic tap
automatic urinal flusher
current transducer
Specifications:
Features:
- Hall effect measuring principle.
- Galvanic isolation between primary and secondary circuit.
- Insulated plastic case made of black PPO recognized according to UL 94-V0.
Certificate:
ISO 9001, ISO 14001
Ordering information:
- Minimum Order: Negotiable
- TEL: 86-574-8738 3998
- FAX: 86-574-8735 9851
- E-mail: sarah-chen@zelrinb.com.cn